More about...
Privacy Notice
Impressum
Contact us
>> Advanced search
Homepage » Catalog » Electrophysiology Your account | English Version |

 
 
Informations
About Sunpoint
News
 Event-Exhibition (2)
 Event-Training (1)
 Nobel visit Sunpoint (1)
 After Hours (5)
 Upcoming Show (1)
Categories
 Animal Physiology (34)
 Electrophysiology (11)
 Animal Behavior (24)
 Animal Test (3)
 Molecular (8)
 Lab Consumables (7)
 Log In (1)
Evaluations
MED64 Multi-electrode system
Very nice site! ..
1 of 5 stars!

Welcome back !
eMail-address:
Password:

New Products

NeuroStar-StereoDrive


 
  聯絡三典科技Contact Us  

Electrophysiology
 
Electrophysiology


 
  Cyberkinetics Neurotechnology Systems

Cyberkinetics Neurotechnology Systems provides turn-key solutions for neuroscience researchers interested in recording neural signals from populations of neurons over a long period of time. Our solution includes Multi-Electrode Arrays, the Cerebus™ 128 Channel Data Acquisition System, and a Surgical Training Program. Our technical sales and engineering staff has over 9 years of experience working with researchers and our products have validated in over 65 academic laboratories around the world.


  Nanion NPC-1 Port-a-Patch

The Nanion Port-a-Patch is a one-cell-at-a-time system, which is surprisingly small for a complete patch clamp rig. Patch clamp recordings in the whole cell configuration, and single channel recordings in the cell attached configuration, can be performed with planar patch clamp chips. The Port-a-Patch is routinely provided with an EPC-10 amplifier from HEKA together with a computer and the software packages. Manual liquid-handling is combined with computer controlled suction supply for automated sealing and whole cell access. An optional Perfusion System and Temperature Control device is available.


  Nanion Patchliner

The Patchliner is Nanion’s fully automated patch clamp workstation with increased throughput and full experimental freedom. The instrument is applicable not only in safety pharmacology and target validation, but also in ion channel research. The system has 2, 4 or 8 amplifier channels to perform simultaneous recordings. It utilizes Nanion’s NPC-16 chips, which apart from the glass chips also comprise microfluidic channels. These enable a rapid and precise compound application to the cell’s external and internal side.


  Narishige IM-300 Microinjector (Programmable)

Narishige IM-300 Multi-functional, motor-driven injector for precise control of small volumes.

Setting the time and pressure in advance makes it possible to inject very small volumes of liquid with great precision. This model's numerous capabilities, including injection, filling up and holding, and varied functions such as foot switching, programming and air distribution, make it suitable for a wide variety of applications. External pressure sources are used, and should be selected according to the experiment.


  MED64 Multi-electrode system

The MED64 System (aka Panasonic MED System), based on microelectrode array technology, will enable you to stimulate and record responses from different areas within a biological sample over days, weeks and months with simple operation. Get reliable, long-term, continuous recording and two-dimensional, real-time analysis of neuronal/myocardial activity. The MED64 is a complete, fully integrated solution. Biological acute or culture preparation are placed directly into the MED probe. The MED64 System is comprised of four components: an integrated amplifier, probe, connector, and a choice of new Software Mobius™ for data acquisition and analysis. Multi-electrode arrays (MEA) are widely used in electrophysiology studies of the central (CNS: e.g. Cortex, Hippocampus; retina, Suprachiasmatic Nucleus, SCN) and peripheral (PNS: e.g. Dorsal Root Ganglion, DRG) nervous system, as well as myocardial and other excitable tissue (e.g. smooth muscle).


  Axon Patch Clamp System

The Axon Instruments microelectrode amplifiers and data acquisition systems are the premier products in their respective categories.


  Michigan Probe

NeuroNexus Technologies offers a variety of probe designs. The extensive design freedom offered by the micromachining technology has resulted in a variety of different probes which satisfy the needs of most investigators.


  Marzhauser Micromanipulators

Sunpoint offers Marzhauser manual and motorized micromanipulators


  Warner Instruments
Warner Instruments, A Harvard Apparatus Company Specialized Tools for Electrophysiology and Cell Biology Research.

  NeuroStar-in vivo electrophysiology

Neurostar gives a special attention to addressing the entire range of needs encountered in modern in-vivo electrophysiology research activities.


  NeuroStar-StereoDrive
NeuroStar StereoDrive is a motorized stereotaxic system. Computer controlled. In all 3 Axes.


Show 1 to 11 (of in total 11 products) Seiten:  1 
 


SUNPOINT SCIENTIFIC INSTRUMENT CO., Ltd © copyright 2006
9F.-1, No.146, Wunsing Rd., Gueishan Township, Taoyuan County 333, Taiwan (R.O.C.)
Tel : 886-3-3273889 (Rep.Line) Fax : 886-3-3273908
sunp55@ms36.hinet.net


TWE-COMMERCE V2.3